Skip to main content
Back to search resultsBill 120328

Amending Title 9 of The Philadelphia Code, entitled "Regulation of Businesses, Trades and Professions," and related provisions of The Philadelphia Code pertinent to electric fences, to provide for the operation and regulation of electric fences, all under certain terms and conditions.

AI summary

Philadelphia enacted rules for the operation and use of electric security fences; the rules do not apply to fences mainly used to contain livestock or zoo animals. Electric security fences must meet limits on power, height, location, surrounding barriers, and warning signs, including a six-foot non-electric fence or wall around them and a ban in residential areas or on properties with a dwelling other than a caretaker’s residence. Violations are Class II offenses, and the ordinance took effect immediately.

File details

Status
ENACTED
Introduced
May 3, 2012
Sponsors
Bobby Henon
View official record ↗

Full text

THE COUNCIL OF THE CITY OF PHILADELPHIA HEREBY ORDAINS:

SECTION 1. Title 9 of The Philadelphia Code is hereby amended to read as follows:

TITLE 9. REGULATION OF BUSINESSES, TRADES AND PROFESSIONS

* * *

CHAPTER 9-3800. ELECTRIC FENCES

* * *

§ 9-3801. Scope. This Chapter provides for the operation of electric security fences. It does not apply to electric fences primarily for the containment of livestock or zoo animals.

§ 9-3802. Regulations. The construction and use of electric security fences shall be allowed in the City of Philadelphia only as provided in this Section, subject to the following standards:

(1) Electrification:

(a) The energizer for electric security fences shall be driven by a commercial storage battery not to exceed 12 volts DC. The storage battery shall be charged primarily by a solar panel, and may be augmented by a commercial trickle charger.

(b) The electric charge produced by the fence upon contact shall not exceed energizer characteristics set forth in paragraph 22.108 of International Electrotechnical Commission (IEC) Standard No. 60335-2-76 and depicted in Figure 102 thereof.

(2) Perimeter fence or wall. No electric security fence shall be installed or used unless it is completely surrounded by a non-electric fence or wall that is not less than six feet in height.

(3) Location. Electric fences shall not be permitted in any residentially-zoned

district or in any property that includes a dwelling other than a caretakers' residence.

(4) Height. Electric security fences shall have a height of no more than 10 feet.

(5) Warning signs. Electric security fences shall be clearly identified with warning signs, at intervals of not less than thirty feet, which shall include the following words prominently displayed: "Warning-Electric Fence." At least one warning sign shall be placed on each side of the fence facing an area accessible to the public.

§ 9-3803. Penalties. A violation of this Chapter shall be a Class II offense.

SECTION 2. This Ordinance shall take effect immediately.

___________________________________

Explanation:

[Brackets] indicate matter deleted.

Italics

indicate new matter added.

End

File history

Sometimes city council's record keeping is not complete. This timeline reflects the information on the council's legistar website.
  1. Council actionMAYOR

    Signed

  2. Council actionCITY COUNCIL

    Ordered placed on next week`s second reading calendar

    Council actionCITY COUNCIL

    Ordered placed on this day`s first reading calendar

    Council actionCITY COUNCIL

    Suspend the rules of the council

    Pass
  3. Council actionCommittee on Public Safety

    Reported favorably, rule suspension requested

    Council actionCommittee on Public Safety

    Amended

    Council actionCommittee on Public Safety

    Hearing held

    Council actionCommittee on Public Safety

    Hearing notices sent

  4. Council actionCITY COUNCIL

    Introduced and Referred

    Pass