Back to search resultsBill 180464

Amending Title 4 of The Philadelphia Code, entitled "The Philadelphia Building Construction and Occupancy Code," by amending Subcode "F" (The Philadelphia Fire Code) and Subcode "PM" (The Philadelphia Property Maintenance Code), to add sections requiring hard-wired interconnected smoke alarms in boarding homes; all under certain terms and conditions.

View file history View official file on Legistar →

File details

Status
Enacted
Type
Bill
Introduced
May 10, 2018
Sponsors
CPCouncil President ClarkeCindy Bass

Full Bill

THE COUNCIL OF THE CITY OF PHILADELPHIA HEREBY ORDAINS:

(Matter added to The Philadelphia Code by these amendments shown in bold;

Matter deleted by these amendments shown by strikethrough).

SECTION 1. Title 4 of The Philadelphia Code is hereby amended to read as follows:

TITLE 4. THE PHILADELPHIA BUILDING CONSTRUCTION AND OCCUPANCY CODE

* * *

SUBCODE "F" (THE PHILADELPHIA FIRE CODE)

* * *

CHAPTER 9

FIRE PROTECTION SYSTEMS

* * *

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

* * *

F-907.1.10 Group R-1, and R-2 and R-3 congregate living facilities. Existing Group R-1 and R-2 congregate living facilities shall have hard-wired, interconnected smoke alarms installed in accordance with NFPA 72 and Section 907.2.11.10.1 or 907.2.1110.2 as applicable of the Philadelphia Building Code. (Group R-l congregate living is up to more than 10 and Group R-2 congregate living is up to more than 16 occupants. See Chapter 2 under Occupancy Classifications for the complete definition of Group R-1 and R-2 congregate living facilities.) Existing Group R-3 congregate living facilities shall have hard-wired, interconnected smoke alarms installed in accordance with F-907.1.10.1.

F-907.1.10.1 Hard-wired and interconnected smoke alarms in existing Group R-3 congregate living facilities. In addition to the requirements of Section F-907.2, hard-wired, interconnected smoke alarms complying with UL 217 shall be installed in accordance with Sections F-907.2.10.1.1 through F-907.2.10.1.3 and NFPA 72 (2016 edition) on each floor, including basements, of existing Group R-3 congregate living facilities.

Exceptions:

1. Buildings equipped with an automatic sprinkler system.

2. Buildings equipped with hard-wired smoke alarms installed in compliance with the Building Code.

F-907.1.10.1.1 Interconnection. The smoke alarms required by this Section F-907.1.10 shall be interconnected in such a manner that the activation of one alarm will activate all of the hard-wired alarms in the facility. Physical interconnection of smoke alarms shall not be required where listed wireless alarms are installed and all alarms sound upon activation of one alarm. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed.

F-907.1.10.1.2 Power source. The smoke alarms required by this Section F-907.1.10 shall receive their primary power from the building wiring provided that such wiring is served from a commercial source and shall be equipped with a battery backup. Smoke alarms shall emit a signal when the batteries are low. Wiring shall be permanent and without a disconnecting switch other than as required for overcurrent protection.

F-907.1.10.1.3 Retrofit of R-3 congregate living facilities. The smoke alarms required by this Section F-907.1.10 shall be installed prior to December 31, 2019. Electrical permits for such installations shall be secured prior to July 1, 2019.

* * *

SECTION 2. Title 4 of The Philadelphia Code is hereby amended to read as follows:

TITLE 4. THE PHILADELPHIA BUILDING CONSTRUCTION AND OCCUPANCY CODE

* * *

SUBCODE "PM" (THE PHILADELPHIA PROPERTY MAINTENANCE CODE)

* * *

CHAPTER 7

FIRE SAFETY REQUIREMENTS

* * *

[F]SECTION PM-704 FIRE PROTECTION SYSTEMS

* * *

PM-704.4 Interconnection. Where more than one smoke alarm is required to be installed within an individual dwelling unit in Group R-2, R-3, or R-4 and in dwellings not regulated as Group R occupancies, the smoke alarms shall be interconnected in such a manner that the activation of one alarm will activate all of the alarms in the individual unit. The alarm shall be clearly audible in all bedrooms over background noise levels with all intervening doors closed.

Exceptions:

1. Interconnection is not required in buildings which are not undergoing alterations, repairs or construction of any kind, except for congregate living facilities as regulated by the Philadelphia Fire Code.

2. Except in congregate living facilities, Ssmoke alarms in existing areas are not required to be interconnected where alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available which could provide access for interconnection without the removal of interior finishes.

SECTION 3. This Ordinance shall be effective October 1, 2018.

End

Timeline

File history

A file can move through several public steps, including introduction, hearings, amendments, votes and final action. This timeline puts those events in date order, groups routine entries from the same day, and attaches published member votes to the action they record.

  1. Council ActionMAYOR

    SIGNED

    Other recorded action without a published tally.

    Official action detail

    Source: LegislationDetail.aspx · gridLegislation

  2. Member voteCITY COUNCIL

    READ AND PASSED

    Member-by-member vote published for this action.

    Pass17 Yes · 0 No · 0 AbsentView member votes →
    Official action detail

    A motion was made that this matter be READ AND PASSED. The motion carried by the following vote:

    Member votes

    MemberVote
    Al TaubenbergerYes
    Allan DombYes
    Blondell Reynolds BrownYes
    Bobby HenonYes
    Brian J. O'NeillYes
    Cherelle ParkerYes
    Cindy BassYes
    Curtis Jones, Jr.Yes
    Darrell L. ClarkeYes
    David OhYes
    Derek S. GreenYes
    Helen GymYes
    Jannie L. BlackwellYes
    Kenyatta JohnsonYes
    Maria D. Quiñones-SánchezYes
    Mark SquillaYes
    William K. GreenleeYes

    Source: LegislationDetail.aspx · gridLegislation

  3. 3 procedural actionsCITY COUNCIL
    ProceduralCITY COUNCIL

    READ AND ORDERED PLACED ON NEXT WEEK'S SECOND READING CALENDAR

    Official action detail

    Source: LegislationDetail.aspx · gridLegislation

    UnanimousCITY COUNCIL

    SUSPEND THE RULES OF THE COUNCIL

    Pass
    Official action detail

    A motion was made by Councilmember Quiñones Sánchez that this matter be SUSPEND THE RULES OF THE COUNCIL. The motion carried unanimously.

    Source: LegislationDetail.aspx · gridLegislation

    ProceduralCITY COUNCIL

    ORDERED PLACED ON THIS DAY`S FIRST READING CALENDAR

    Official action detail

    Source: LegislationDetail.aspx · gridLegislation

  4. 3 procedural actionsCommittee on Licenses and Inspections
    ProceduralCommittee on Licenses and Inspections

    REPORTED FAVORABLY, RULE SUSPENSION REQUESTED

    Official action detail

    Source: LegislationDetail.aspx · gridLegislation

  5. UnanimousCITY COUNCIL

    Introduced and Referred

    Marked unanimous; no member-by-member tally published.

    Pass
    Official action detail

    A motion was made by Councilmember Bass that this matter be Introduced and Referred to the Committee on Licenses and Inspections. The motion carried unanimously.

    Source: LegislationDetail.aspx · gridLegislation

180464: Amending Title 4 of The Philadelphia Code, entitled... | PHL Council Votes